{"product_id":"eastwood-welding-flow-meter-universal","title":"Eastwood Welding Flow Meter — 10-60 SCFH Argon\/CO2 Regulator, CGA 580 | Universal","description":"\u003cp\u003e\u003cstrong\u003eThe Eastwood 20277 welding flow meter is a regulator that reads actual shielding gas flow from 10 to 60 SCFH for argon, argon\/CO2 mixes and straight CO2. It has a CGA 580 inlet, a 5\/8 in x 18 internal right-hand thread outlet, a 2 in gauge reading to 4500 psi and outlet pressure pre-set at 50 psi. Universal for any MIG or TIG welder.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart numbers:\u003c\/strong\u003e Eastwood 20277 · UPC 607174160846\u003c\/p\u003e\n\u003ch3\u003eFitment\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eYears\u003c\/th\u003e\n\u003cth\u003eVehicle\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eUniversal\u003c\/td\u003e\n\u003ctd\u003eAny MIG or TIG welder running argon, argon\/CO2 or CO2 from a CGA 580 cylinder\u003c\/td\u003e\n\u003ctd\u003eNot vehicle-specific\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eEastwood 20277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e607174160846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow range\u003c\/td\u003e\n\u003ctd\u003e10-60 SCFH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGases\u003c\/td\u003e\n\u003ctd\u003eArgon, argon\/CO2, CO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet\u003c\/td\u003e\n\u003ctd\u003eCGA 580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet\u003c\/td\u003e\n\u003ctd\u003e5\/8 in x 18 internal right-hand thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet pressure gauge\u003c\/td\u003e\n\u003ctd\u003e0-4500 psi (0-31500 kPa), 2 in diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet pressure\u003c\/td\u003e\n\u003ctd\u003ePre-set at 50 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow tube\u003c\/td\u003e\n\u003ctd\u003eShatter-resistant polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhy It Matters\u003c\/h3\u003e\u003cp\u003ePorosity and grey, sooty welds usually come down to shielding gas, and a plain pressure regulator only tells you what is in the bottle, not what is reaching the arc.\u003c\/p\u003e\u003cp\u003eA flow meter reads actual flow in SCFH so you can set the gas where it should be, stop guessing, and stop emptying a bottle in a weekend.\u003c\/p\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cp\u003eThread the CGA 580 inlet onto the cylinder and connect the welder's gas hose to the 5\/8 in x 18 outlet. Outlet pressure is pre-set at 50 psi, so it is ready to run out of the box.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich gases does the Eastwood 20277 flow meter handle?\u003c\/strong\u003e\u003cbr\u003eArgon, argon\/CO2 mixes and straight CO2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill the welding flow meter screw onto my bottle?\u003c\/strong\u003e\u003cbr\u003eThe inlet is CGA 580, the standard fitting on inert gas cylinders. The outlet is 5\/8 in x 18 internal right-hand thread.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat flow range does the flow meter cover?\u003c\/strong\u003e\u003cbr\u003e10 to 60 SCFH, which covers normal MIG and TIG shielding rates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy use a flow meter instead of a pressure regulator?\u003c\/strong\u003e\u003cbr\u003eA pressure regulator only shows what is in the bottle. A flow meter reads actual gas flow in SCFH, so you can set shielding gas correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it need adjusting before first use?\u003c\/strong\u003e\u003cbr\u003eThe outlet pressure is pre-set at 50 psi, so it is ready to run out of the box.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShop more:\u003c\/strong\u003e \u003ca href=\"\/collections\/restoration-tools\"\u003eRestoration Tools\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProp 65 WARNING:\u003c\/strong\u003e This product can expose you to chemicals known to the State of California to cause cancer and reproductive harm. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e","brand":"Eastwood","offers":[{"title":"Default Title","offer_id":45401159794803,"sku":"20277","price":112.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/2760\/1523\/files\/p20277_5.jpg?v=1787722259","url":"https:\/\/www.washburnsmetal.com\/products\/eastwood-welding-flow-meter-universal","provider":"Washburn's Metal","version":"1.0","type":"link"}